F5 Cetane Rating System with XCP Technology

F5 Cetane Rating System

with XCP® TECHNOLOGY

This test method is used by engine manufacturers, petroleum refiners and marketers, and in commerce as a primary specification measurement related to the matching of fuels and engines.

The cetane number is determined in a precombustion chamber type compression ignition test engine at a constant speed. This method can be used for conventional middle distillate Diesel fuel, jet kerosene fuels, blending feedstocks, as well as unconventional fuels like synthetics, vegetable oils, and bio-diesel. 

This test method involves determining the quality of diesel fuel using a standard single cylinder four-stroke cycle variable compression ratio, indirect injection diesel engine. The quality is measured on an arbitrary scale of cetane numbers, ranging from 0 to 100. However, typical testing is usually conducted within the range of 30 to 65 cetane number.

Download Product Details

The CFR F5 cetane rating engines are specified equipment for testing fuels according to:

ASTM D613:
Standard Test Method for Cetane Number of Diesel Fuel Oil
IP 41:
Petroleum Products - Determination of the ignition quality of diesel fuels - Cetane Engine Method
EN ISO 5165:
Petroleum Products - Determination of the ignition quality of diesel fuels - Cetane Engine Method
Image
Image
Image
Image
Image
Image
Image
Image
Features & Benefits

Features & Benefits

robust engine crankcase and cylinder head

The F5 is the dependable choice, featuring a robust engine crankcase and cylinder head designed for unparalleled operating life.

digital instrument control system
The digital instrument control system delivers a host of benefits, including on-board handwheel position recording, automatic cetane number calculation, and multi-pass data recording.
Ready-to-use Excel-based reports generated, minimize calculation errors and the need to manually record data
XCP® TECHNOLOGY generates ready-to-use Excel-based reports that effectively minimize calculation errors and eliminate the need for manual data recording.
Built-in prompts, clear graphics, and color-coded indicators simplify the fuel rating
The fuel rating system is made clear and simple with built-in prompts, clear graphics, and color-coded indicators.

F5 Cetane Details

Standard CFR F5 System Inclusions:

  • Engine unit mounted to rigid base

  • Synchronous motor mounted to slide base (220/380/440V; 3 Ph; 50/60 Hz)

  • Variable compression ratio cylinder head with handwheel

  • Handwheen position sensor

  • XCP panel with touchscreen PC (120V, 1 Ph, 50/60 Hz)

  • Fuel shut-off solenoid

  • Three bowl fuel delivery system

  • Intake air heater

  • Exhaust surge tank system

  • Water cooled exhaust manifold

  • Desk with keyboard and mouse

 

Motor Method (ASTM D613)

RPM

900 +/- 1%

Injection Timing

13 BTDC

Water Jacket Temperature

100 °C +/- 2 °C (212 °F +/- 3 °F)

Oil Temperature

57 °C +/- 8 °C (135 +/- 15 °F)

Oil Pressure

172 kPa-207 kPa (25 psi-30 psi)

Crankcase Vacuum

25-150 mm H2O (1-6 in H2O)

Intake Air Temperature

66 °C +/- 0.5 °C (150 °F +/- 1 °F)

Nozzle Passage Temperature

38 °C +/- 2.8 °C (100 °F +/- 5 °F)

  • Approximately 1.77 x 1.33 x 1.04m (H x W x D), 844 kg;
    (69 ¾ x 52 ¼ x 41 in, 1860 lb)

  • Including concrete base: approximate height 2.15 m
    (84 ¾ in), weight 1754 kg (3860 lb)

  • With exhaust surge tank: approximate depth 1.57 m (62 in)

Accessories & Optional Equipment

Gravimetric Blending System (GBS)

Gravimetric Blending System (GBS)

Offering unmatched precision of +/- 0.2% for the blending of primary, secondary, and standard reference fuels gravimetrically.

Learn More
Volumetric Blending System (VBS)

Volumetric Blending System (VBS)

The blending of primary, secondary, and standard reference fuels volumetrically.

Learn More
XCP® TECHNOLOGY

XCP® TECHNOLOGY

Taking integrated data to the next level, this advanced system automatically captures data, eliminating manual adjustments and human errors.

Learn More
Eager to learn more about the CFR F5 Cetane Rating Engine? The CFR Training Academy offers a variety of hands-on courses to enhance your skills. Register for training today!

Eager to Learn More?

The CFR Training Academy offers a variety of hands-on courses to enhance your skills.
 

Register for training today!

Contact CFR to learn more about the F5 Cetane Rating System

Contact CFR to learn more about the F5 Cetane Rating System

Call +1 262.501.5998 or complete this form and we'll get back to you quickly!

In the News

Providing Integration and Flexible Solutions
Editorials

Providing Integration and Flexible Solutions

XCP®- More than Just the Method
Editorials

XCP®- More than Just the Method

Preserving your Engine with Preventative Maintenance
Editorials

Preserving your Engine with Preventative Maintenance